agrounikwater treatmentcert

Water treatment

Chlorine gas detector dh-2003

  • gas chlorination devices
  • dosing systems
  • automatic systems for chlorination and measurement devices
  • scada systems remote control and data transfer
  • production of sodium hypochlorite from salt
  • compact units for waste water treatment

chlorine gas detectorschema

Chlorine gas detector is designed to detect the chlorine presence and to continuously measure chlorine concentration within the zone under supervision (for example, room with chlorine dosing equipment or storage room for full / empty chlorine cylinders). It is capable to detect very low chlorine concentrations, below 0.5 ppm. This device allows the user to set up two completely independent alarm levels, at which will be activated two independent relay contacts, that can turn on external sound / light alarm devices, fans or special devices for the automatic neutralization of chlorine present in the air. Measured concentration is shown on the detectors display in the range of 0 – 10 ppm.

The device consists of two parts: measuring sensor – chlorine detector probe HS-25-09 and electronic microprocessor receiver – chlorine detector DH-2003.

Characteristics:

  • Measuring range: 0-10 ppm
  • Measurement resolution: 0.01ppm
  • Chlorine detector probe with transmitter
  • Response time: 50sec
  • Digital LED display
  • Independent adjustment of two limits
  • Light indication alarm
  • Indication of probe failure
  • Continuous measurement of chlorine in the air
  • High reliability

Technical data:

chlorine detector electronics dh-2003
Power supply: 220 VAC ± 10%, 50 Hz, single-phase
Power consumption: 4 VA
Input signal: 4 – 20 mA
Output signal: 4 – 20 mA
Output for probe power supply: 12 VDC / 60 mA max.
Stabilization time of measurement: minimum 180 sec
Alarm Relay Contacts: 2 relays with changeover contacts, 250V/2A, AC/DC
LED display: 3 digits, red color, size 12.5 mm
LED indicators: Alarm 1: turned on/probe malfunction, Alarm 2: turned on
Ambient temperature: -15 – 450C
Housing: ABS plastics, IP65 protection
chlorine detector probe hs-25-09
Sensor: CLH7, sensitive to chlorine (Cl2)
Measuring range: 0 – 10 ppm
Maximum concentration: 50 ppm
Operating temperature: -20 do 500C
Permitted relative humidity: 15% do 90% R.V.
Response time: <60 for 80% of the current concentration at 200C, relative humidity 50% and 1013 mbar
Expected probes lifetime: two years in the air (without constant exposure to chlorine)
Connection cable: 2 x 0,75 mm2
Electrical connection: 4 – 20 mA pri 12 V DC (max: 35V)
Maximum distance: up to 200 m
Probe orientation: vertical, directed down
Installation height: about 0.4 m above the floor
Housing: PVC, IP65 protection

Comments are closed.